In vitro comparison of primary stability of two implant designs in D3 bone
2016
Background Primary stability (PS) is a key factor for implant survival rate and depends on implant design or bone quality. The aim of this study was to compare different thread designs implants, evaluating PS with periotest values (PV) and implant stability quotient (ISQ) values through resonance frequency analysis (RFA). Material and Methods A total of 60 implants (Radhex®, Inmet-Garnick S.A., Guadalajara, Spain) were placed in freshly bovine ribs in vitro. Two designs were used: 30 tapered body with single thread design (PHI) and 30 tapered body with double thread design implants (PHIA). Both designs were 4mm wide and 12mm long. Implants were placed according to manufacturer’s guidelines.…
The anatomy of the proximal radius: implications on fracture implant design.
2012
Background The proximal radius features a complex anatomy. Several studies have been published on the anatomy using different technical approaches; however, most of these studies were conducted with a special focus on parameters relevant to radial prosthetic design. The purpose of our study was to explore the complex geometry of the proximal radius with regard to fracture implant design. Methods Our computed tomography-based measurements of 78 multiplanar reformatted radii allow for exact assessment of its geometry and offer a scientific rationale towards the design of fracture implants. We conducted measurements on the radial head, the radial neck, the radial tuberosity, the radial head-to…
Effect of implant macro-design on primary stability: A prospective clinical study
2016
Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by…
Immediate loading implants: Review of the critical aspects
2018
Purpose. Modern dentistry have witnessed, a rapid and continuing evolution. Concerning the implant-rehabilitation protocols, they have beenEdizioniredefined in order to satisfy patientâs increasing expectations in terms of comfort, aesthetic and shorter treatment period. The purpose of this review is to explore the concept of implant immediate loading and the indications for clinical practice. All the critical aspects that could influence the outcomes of this treatment will also be considered. Materials and methods. Three protocols for implant load timing have been classified: immediate loading implants (ILI); early loading implants (ELI); and conventional loading implants (CLI). Two subc…
Immediate Nonfunctional Loading of NobelPerfect Implants in the Anterior Dental Arch in Private Practice - 5-Year Data
2012
Background: The concept of scalloped implants to maintain the natural contour of the alveolar ridge has been a source of controversy for many years. Purpose: This study examined the long-term clinical performance of the scalloped NobelPerfect implant in a one-stage procedure (immediate loading in the esthetic zone). Materials and Methods: In 20 patients, immediate prosthetic restorations were placed on 31 NobelPerfect implants in a private practice and followed for up to 78 months. Twenty-one implants were placed immediately after extraction, seven implants were placed after osseous consolidation of the extraction sockets, and three implants were placed secondary to extended alveolar ridge …
Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency an…
2020
Background This study aimed to evaluate the effect of the implant design and the presence of cortical bone in the primary stability, as well as analyze the differences between the stability measurements obtained by two different resonance frequency analysis (RFA) devices. Material and methods A total of 80 Klockner implants of two different models [40 Essential Cone implants (group A) and 40 Vega implants (group B)] were used. The implants were placed in two polyurethane blocks that simulated the mechanical properties of the maxillary bone. One block featured a layer of cortical bone that was absent from the other block. The primary stability of all implants was measured by insertion torque…
Primary Stability of a Hybrid Self-Tapping Implant Compared to a Cylindrical Non-Self-Tapping Implant with Respect to Drilling Protocols in an Ex Viv…
2011
Background: Modifications of implant design have been intending to improve primary stability. However, little is known about investigation of a hybrid self-tapping implant on primary stability. Purposes: The aims of this study were to evaluate the primary stability of two hybrid self-tapping implants compared to one cylindrical non-self-tapping implant, and to elucidate the relevance of drilling protocols on primary stability in an ex vivo model. Materials and Methods: Two types of hybrid self-tapping implants (Straumann® Bone Level implant [BL], Straumann® Tapered Effect implant [TE]) and one type of cylindrical non-self-tapping implant (Straumann® Standard Plus implant [SP]) were investig…
Drilling dimension effects in early stages of osseointegration and implant stability in a canine model
2015
Background: This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols. Material and Methods: Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linea…